Specifications

* Long-life amplified ion current tester
* Automatic temperature compensation
* No need benchmark gas

CI400 Flue Gas Analyzer

Introduction                                                                                                  

CI400 analyzer measures oxygen concentration without benchmark gas by adopting amplified ion current with the world advanced technology as measurement principle. It has observable characteristics of long calibrating period, high precision, small appearance and low power less and automatic temperature compensation.

Features                                                                                                      

* New pattern, long-life, amplified ion current tester with high sensitivity and fast response

* High precision, automatic temperature compensation, eliminating the impact of environmental temperature

* Checking the sensor working state automatically and unique double-line working change mode extending the sensors life.

* Concise menu, simple operation

* Connected to a printer via the standard (4-20)mA, RS232 and RS485 interfaces. 

* Setting upper and lower alarm values freely during the measure ranges

* No need benchmark gas.

Technical Specifications                                                                                       

Measure Range:                   0-5.00%, 0-10.00%, 0-25.00% O2

Accuracy:                           ≤±2% in FS range

Response Time:                   90% of FS reading ≤ 20 seconds

Repeatability:                      ≤1%

Stability:                            Zero drift ≤±1% of FS/7d

                                         Span drift ≤±1% of FS/7d

Preheating Time:                 99s

Working Temp.:                  0~300oC

Signal Output:                     4-20mA or 0-5V DC isolated

Contact Capacity:                125VAC 0.3A, 110VDC 0.3A, 30VDC 1A

Power Supply:                     220±10% VAC, 50/60Hz, power loss≤10VA

Detector Length:                   0.4m, 0.6m, 0.8m, 1.0m, 1.2m, 1.5m

Ambient Temp.:                   -10~+45oC

Appearance Dimension:        220mm×292mm×87mm (W×H×D) (Analyzer)

Weight:                               4kg

Installation Mode:                  Inserting detector and wall-mounting analyzer

Applications                                                                                                 

This oxygen analyzer is used to continuously measure oxygen concentration in combustion gas of industrial boilers or furnaces, and is ideally suited for combustion monitoring and control.

Kind Fuels Requests Excessive Air                                                                              

Fuel type

Excessive Air

Excessive oxygen content

Natural gas

5~10%

1~2%

Liquid fuel

8~15%

2~3%

Coal

10~40%

2~6%

Coke

20~40%

4~6%

Enter your inquiry detailssuch as:

Send message to this supplier

To:
Ben Lee
*Message:
-Enter between 20 to 2000 characters. English only. character(s).
 
Send

Latest Products

GNL-500F CO2 Analyzer
SP-980L High Pirity Oxygen Analyzer
GNL-B3/YF1 Process Trace Oxygen Analyzer
Series B Desktop Wall Mount Enclosures
GNL-DC1 online dew point monitor
Hot Selling Server Cabinet

Selected(1/4)Contact or Compare